Ⅰ. Summary
This machine was used in department of environment protect、sanitary and ant epidemic, drug supervision, marine lives. It is the special equipment for Liquid test and culture, save the BOD test, Bacillus, Mold, Microorganism.
Ⅱ. Structure features
1. The case is adopts high quality cold-rolled steel plate with the plastic spraying on the surface.
2. Mirror-stainless working room, easy clean, Shelves can be adjusted.
3. Micro-Computer Tem. Controller and Automatic defrosting system, can make sure the high precise and working continue, big LCD Screen.
4. Sole Tem. limited alarm system、Over-Tem. cut off electric and timing function, can make sure the safety operate.
5. R134A famous compressor and fans.
6. Double doors, inner door is the good quality steel-glass, silicon seal, outside door is the magnetic silicon, easy open and close, make sure the good seal.
7. ¢50mm big test hole, can test the chamber line、power and other condition.
8. Optional function
①RS-485/232 connector, can contact with the computer
②Typer (mini size)
③Alarm system when electric cut off.
④Cut off electric or Alarm function when open the door
⑤Creepage protect
The above Optional parts should be made by our company.
Ⅲ. Working Condition
1. Environment Temp.: 5~32℃ (if setting tem.≦10℃,environment≦28℃).
2. Humidity:≦80%RH 3. Air Presser: 80-106Kpa
4. There was no shake of the incubator and not caustic air around the chamber.
5. Should avoid light and cooling environment.
6. Keep distance of the dust, install horizontal and make sure a distance between the equipment and wall.
7. Good airiness.
Ⅳ. Safety information
1. After you received the equipment, to avoid the damage for the compressor during a long transport, please keep the machine leave 1 days and then can use. To make sure equipment and test safety, please install the outer protect and also use the power as the equipment required.
2.Do not test the flammable and combustible、poisonous
and corrosive material.
3.The equipment should be installed horizontal.
4.Only the engineer can disassembly and repair.
5.If put one working equipment into the chamber, once the
power bigger than 2A, please add the power outside, please do not use this equipment power.
6.When the chamber tem.≧50℃, please do not setting the
low tem. to avoid the compressor working, to make sure the compressor can be used long time.
7.Once alarm operates, please resolve this problem; please
do not turn on the machine.
8.Please read this manual operation and then operate this
machine
Ⅴ. Operation cautions
1. There has the test hole (Humidity hole), when put the other equipment into the chamber, please through this hole, and make sure the test hole humid.
2.First turn on the machine, please do not change the
system specification if the manual operation do not refer.
3.U.V. lamp close once do no need use to avoid influence the
Tem.
4.Before do the cooling operate, please dry the chamber 1
hour under the 50 degree.
5.The Chamber with the vertical air system, Please do not
put full material on the shelf, the test material less than 1/3 of the shelf.
6.Once the test environment﹥35℃ or Use Tem.﹥50℃,
forbid setting the low tem.
7.Please use the pure water clean the chamber and surface
of the machine. When the machine does not used, please cut off the Electricity, and make sure the inner and outer clean and dry.
Ⅵ. Product Specification
Model
|
SPX-70BⅢ
|
SPX-150BⅢ
|
SPX-250BⅢ
|
Voltage
|
220~240V 50Hz/60Hz
|
Tem. Range
|
0-65℃
|
Tem. Motion
|
±0.5℃
|
Tem. Uniformity
|
±1℃
|
Cryogen
|
R134a
|
Power
|
800W
|
1000W
|
1200W
|
Inner Chamber size (cm)
|
42*35*50
|
50*60*60
|
60*50*84
|
Exterior Size (cm)
|
57*56*103
|
64*62*129
|
82*76*145
|
If you are interested in the product and need detailed English user's manual for the product,Please contact us, thank you.
|